- Home
- /Troponin T.cardiac
Troponin T.cardiac
The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit. The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit (URL) [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966] This term is based on, but not restricted to, Roche's Troponin T high sensitivity test.
Overview
The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit. The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit (URL) [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966] This term is based on, but not restricted to, Roche's Troponin T high sensitivity test.
Related Health Conditions
Conditions where Troponin T.cardiac is commonly tested
Related Health Goals
Treatments & Interventions
Therapies monitored using Troponin T.cardiac
Technical Information (LOINC Codes)
Standardized laboratory codes for this biomarker
6598-7Primary33204-96597-948425-348426-167151-189575-5106734-7101915-7Available Lab Tests
Order tests that measure this biomarker
Find Specialists
Doctors who commonly order this test