Troponin T.cardiac

ChemistryAlso known as: Troponin T 6h SerPl-mCncAlso known as: Troponin T Bld QlAlso known as: Troponin T Bld-mCncng/L

The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit. The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit (URL) [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966] This term is based on, but not restricted to, Roche's Troponin T high sensitivity test.

Normal Range
Consult your provider
ng/L
Abnormal Levels
Consult your provider
Specimen Type
Blood

Overview

The "high sensitivity" troponin assays manufactured by different vendors have different analytical characteristics, including the limit of detection and 99% upper reference limit. The quantitative results from different assays should not be compared to make clinical decisions, and reporting the quantitative result in isolation is not recommended. The troponin high sensitivity quantitative results should be reported with information about the assay and/or the interpretation, depending on the specific reporting method used in a given laboratory or hospital, that are included in the High sensitivity Troponin I [LOINC: 89577-1] and Troponin T [LOINC: 89576-3] panels. 1. The laboratory device 99th percentile upper reference limit (URL) [LOINC: 89581-3] 2. The laboratory device coefficient of variation at 99th percentile URL [LOINC: 89580-5] 3. The laboratory device detection limit [LOINC: 87706-8] 4. Interpretation for troponin T [LOINC: 89575-5] and/or troponin I [LOINC: 89578-9] [PMID: 25204966] This term is based on, but not restricted to, Roche's Troponin T high sensitivity test.

Related Health Conditions

Conditions where Troponin T.cardiac is commonly tested

Related Health Goals

Technical Information (LOINC Codes)

Standardized laboratory codes for this biomarker

6598-7Primary
Troponin T.cardiac [Mass/volume] in Serum or Plasma
ug/L;ng/mL
33204-9
Troponin T.cardiac [Presence] in Serum or Plasma
6597-9
Troponin T.cardiac [Mass/volume] in Venous blood
ug/L
48425-3
Troponin T.cardiac [Mass/volume] in Blood
ug/L
48426-1
Troponin T.cardiac [Presence] in Blood
67151-1
Troponin T.cardiac [Mass/volume] in Serum or Plasma by High sensitivity method
ng/L
89575-5
Troponin T.cardiac [Interpretation] in Serum or Plasma Qualitative by High sensitivity method
106734-7
Troponin T.cardiac [Mass/volume] in Serum, Plasma or Blood by Rapid immunoassay
ug/L
101915-7
Troponin T.cardiac [Mass/volume] in 6 hour Serum or Plasma
ng/L

Available Lab Tests

Order tests that measure this biomarker

Find Specialists

Doctors who commonly order this test